Mobile racking storage system
Jracking electric mobile rack storage system is easy to control, safe and reliable. The system is composed of 100% selective pallet rack mounted on mobile based that move along tracks installed into the floor. With racks moving on the racks, an access aisle can be formed between the appropriate racks.
Specification
Guide rail | Non-Guide rail | |
Loading capacity | 32tons/unit | 16tons/unit |
Wheel material | Cast iron | Polyurethane |
Width of trolley | 210/226mm | 300mm |
Cost | Normal | High |
Running speed | 10m/min | |
Notch | Need | No need |
Guidance | Rail guidance | Mechanical guidance |
Power of motor | 0.4KW/0.75KW/1.5KW |
Application
1. Multiple types of products with small quantity
2. 100% sorting rate
3. Little space, high accessing rate
4. Frequent earthquake area
5. Manufacturing industry
6. Food and drug industry
7. New energy industry
Raw material | Cold room for food |
Finished-parts storage | Long material and extrudate |
Advantages of JT RACKING Electric Mobile Rack Storage System:
1. Storage capacity is much larger than the average fixed shelves, saving space.
2. Suitable for a small amount of low-frequency custody.
3. Save the floor area, the ground utilization rate of 80%.
4. Direct access to each item, not limited by the FIFO.
5. Per unit area of storage can be raised to about 2 times fixed pallet racking.
6. Simple structure, easy to operate.
List of abnormal information
NO. | Information | Reason | Solution | Referer | Level |
1 | Abnormal CPU | CPU fault | Change the PLC | A | |
2 | Inoperable | System crash | Restart | C | |
3 | Not flexible | Abnormal button | Touch screen fault | A,C | |
External pressure leads to deformation | |||||
Change the button of panel | |||||
4 | Stop too far or hit | Abnormal slow/stop sensor | Adjust action distance of sensor | B | |
Check the contact and replace the sensor | B | ||||
5 | Abnormal Anti-falling sensor | Light of sensor cannot be aimed | Adjust light and clean the dirt | C | |
Poor contact of sensor | Check connecting plug | B | |||
Falling objects shade the light | Take out the objects | B | |||
Fault of sensor | Change the sensor | A | |||
6 | Abnormal entering sensor | Light of sensor cannot be aimed | Adjust light and clean the dirt | C | |
Poor contact of sensor | Check connecting plug | B | |||
Shade the light | Take out objects from sensor | B | |||
Fault of sensor | Change the sensor | A | |||
7 | Abnormal transducer | Overload | Normal load | C | |
Objects in the aisle | Take out the objects | C | |||
Rail settlement | Adjust vertical of rail | A | |||
Communication cable was broken between the trolleys | Check the cable | B | |||
8 | Abnormal derailment | Abnormal supply voltage | Check power voltage | B | |
Derailment | Check the drive load balance | C | |||
Magnetic guide sensors deviate from the magnetic stripe | Manual operation, guide trolley to magnetic sensor | C | |||
Objects in the aisle | Take out the objects | C | |||
9 | Abnormal runtime | Partial load or driving wheel is floating | Check the drive load balance | C | |
Setting of ground or damage | Repair the ground | A,C | |||
Trolley has not been moved in set time | As same as abnormal transducer | C | |||
10 | Emergency stop button On/ Auto power OFF | Not continuous working in set time | Key switch OFF,restart for few seconds later | A | |
Press emergency stop button | Reset emergency stop button | C | |||
Disconnection | Check the wiring if cannot reset | B | |||
Emergency button is broken | Change the button | C |